|  Help  |  About  |  Contact Us

Publication : Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Ca(v)3.2 voltage-gated Ca(2+) channel.

First Author  Papazoglou A Year  2021
Journal  Data Brief Volume  36
Pages  107027 PubMed ID  33948455
Mgi Jnum  J:386652 Mgi Id  MGI:8348457
Doi  10.1016/j.dib.2021.107027 Citation  Papazoglou A, et al. (2021) Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Ca(v)3.2 voltage-gated Ca(2+) channel. Data Brief 36:107027
abstractText  This article provides raw relative electroencephalographic (EEG) power, temperature and activity data from controls and Ca(v)3.2 deficient mice. Radiotransmitter implantation was carried out in male experimental mice under ketamine/xylazine narcosis. Following a recovery period, radiotelemetric EEG recordings from the hippocampal CA1 region were obtained under spontaneous 24 h long-term conditions and post urethane injection. Relative EEG power values (%) for 2 s epochs were analysed for the following frequency ranges: delta 1 ( delta1 , 0.5-4 Hz), delta 2 ( delta2 , 1-4 Hz), theta 1 ( theta1 , 4-8 Hz), theta 2 ( theta2 , 4-12 Hz), alpha ( alpha , 8-12 Hz), sigma ( sigma , 12-16 Hz), beta 1 ( beta1 , 12-30 Hz), beta 2 ( beta2 , 16-24 Hz), beta 3 ( beta3 , 16-30 Hz), gamma low ( gammalow , 30-50 Hz), gamma mid ( gammamid , 50-70 Hz), gamma high ( gammahigh , 70-100 Hz), gamma ripples ( gammaripples , 80-200 Hz), and gamma fast ripples ( gammafast ripples , 200-500 Hz). In addition, subcutaneous temperature and relative activity data were analysed for both the light and dark cycle of two long-term recordings. The same type of data was obtained post urethane injection. Detailed information is provided for the age and body weight of the experimental animals, the technical specifications of the radiofrequency transmitter, the stereotaxic coordinates for the intracerebral, deep and epidural, surface EEG electrodes, the electrode features, the filtering and sampling characteristics, the analysed EEG frequency bands and the data acquisition parameters. EEG power data, temperature and activity data are available at MENDELEY DATA (doi:10.17632/x53km5sby6.1, URL: http://dx.doi.org/10.17632/x53km5sby6.1). Raw EEG data are available at zenodo (https://zenodo.org/).
Quick Links:
 
Quick Links:
 

Expression

Publication --> Expression annotations

 

Other

4 Bio Entities

Trail: Publication

0 Expression